Table Log Component

User rating:
1.9 (18 ratings)

Displays incoming messages in a tabular format. From TableLog component layout you can save current TableLog buffer. It is limited to save memory, specially since a lot of data is coming in very short period of time. Default value is one thousand lines. In component setting you can modify its behaviour: increase/decrease buffer size, choose if results should be saved in file, in this case all data that comes in are saved in csv format to file, should be report file appended.

loadUI TableLog Component


OptionDescription
1_snag_evi
Input Data for Display
2_snag_evi Table Display
A new column will be created for the new value
3_snag_evi Reset Button
Resets the Table
4_snag_evi Clear Button
Clears all the columns
5_snag_evi Follow checkbox
If enabled, the display will scroll to each new line

Compact View

TableLogCompactComponent


OptionDescription
1_snag_evi
Input Data for Display
2_snag_evi Rows Display
The number of rows in the table
3_snag_evi File name
The name of the file the table is saved to

Settings

General

TableLogGeneral


OptionDescription
1_snag_evi
Max Rows The Maximum number of rows to display in the table
2_snag_evi Max Rows in Summary
The Maximum number of rows to display in the summary after the test is complete

Logging

TableLogLogging


OptionDescription
1_snag_evi
Save Logs Determines whether the logs should be saved to a file
2_snag_evi File Name
The name of the file to save the logs to (ignored if log saving is disabled)
3_snag_evi Append to file
If this is enabled, the log is appended for each run, otherwise a new file is started for each run, ignored if logging is disabled)

Advanced

TableLogAdvancedProperties


OptionDescription
1_snag_evi
Description
2_snag_evi Save File True if the table contents should be saved to a file
3_snag_evi Append to Save file
If this is true, the log is appended for each run, otherwise a new file is started for each run, ignored if logging is disabled)
4_snag_evi Maximum Rows
The maximum number of rows in the table
5_snag_evi File Name
The name of the file to save the table contents to (ignored if saving is disabled)
4_snag_evi Summary Rows
The number of rows to include in the summary
5_snag_evi Follow 
If true, the display will scroll to each new line

Input

  • The messages to be displayed in the table

Controls

  • Table - The table will display the source runner and component for every message received, as well as the contents of that message.
  • Follow Checkbox - If checked, the table view will automatically scroll down as new rows get added.
  • Clear - Deletes the data from the table, but leaves the columns
  • Reset - Clears the data and the columns

Settings

  • Max Entries – The maximum number of entries to display in the table. If there are more messages that this, the earliest ones are removed to make room.
  • Output File - if specified all rows will be written to this file in csv format. Max Entries will have no effect on this file